Category Archives: Construction

Finding Roof Leaks

Roof leaks are a important headache to fix. The great news is that some leaks are predictable – particularly as the roof ages. By identifying places that are prone to building difficulties, steps can be taken that will prevent roof complications expense efficiently.

Visit for more information: nyt tag.

Appear For Roof Leaks Close to Penetrations Flashings and sealants at penetrations by means of the roof membrane are typical difficulty spots. Commonly in single-ply roofing systems, penetration flashings are the exact same material as the roof membrane and are bonded to the field membrane. Inspect the laps, seams and sealants at these locations frequently. Factory-assembled boots can address field installation issues at penetrations. It is crucial that technicians properly seal the boot to the field membrane, where problems usually occur. Roof drains that penetrate a roof membrane can be specially troublesome because rain that falls onto the roof eventually flows over the drain’s seal. Drains should be significant enough to manage heavy rainfalls, and they ought to have a screen that stops debris from flowing down the pipe. Workers need to clean the drain regularly to stop blockage of the screen and set up recessed drain sumps. A optimistic slope in the roof also can protect against ponding around drains. The greatest way to avoid leaks at roof penetrations is to keep away from penetrations altogether. For instance, ducts, conduits and other piping that runs horizontally across the roof generally are placed on strong supports that are anchored to and penetrate the roof membrane at normal intervals.

To steer clear of these penetrations, managers can specify merchandise with adjustable heights and soft feet that rest on the membrane. If a horizontal element ought to be anchored to the roof, make a curb and secure the element supports to the curb. Roof Leaks On The Perimeter Leaks take place close to roof edges because of the transition from flexible membrane flashings to inflexible sheet-metal flashings. Technicians need to make sure that sheet-metal laps shed water, and they ought to inspect the sealants at these places regularly. Pre-manufactured sheet-metal roof accessories can resolve quite a few roof-perimeter difficulties. Managers can specify custom-created accessories for copings at parapet walls and reglets at masonry or interior increasing walls. These elements ordinarily snap together, and technicians can dismantle and re-set up them during roof-membrane replacements. Water difficulties also happen near expansion joints at roof perimeters. To address areas exactly where building expansions and contractions are most likely to happen, managers may possibly want to to take into account specifying pre-manufactured roof accessories. But managers will need to make positive accessories they specify are compatible with the roof membrane. Condensation And Roof Leaks At times, a roof may seem to leak in January when the temperature dips below freezing, but the roof may not be leaking. What happens is condensation is developed when the warm, moist interior air inside the developing contacts cold surfaces or when cold air leaks by way of the building’s exterior skin. This difficulty may outcome from a missing or inadequate air barrier or vapor retarder on ceilings or walls, or from inadequate insulation or ventilation. Cold places above the insulation in joist cavities or attic spaces have to be vented. If organic ventilation is complicated or too expensive, technicians can install a fan that moves moist air out of the cold space. Continue reading Finding Roof Leaks

DEWALT DWFP12658

If you wish to bring your roof to a new level, you must buy a practical system.

The DEWALT DWFP12658 has been given to produce your shingles shine all the time, and that´s what you need to see today. So you should read on more information about the DEWALT DWFP12658.

Read more here: DEWALT DWFP12658

“Compact Body Design”
The DEWALT DWFP12658 gives you the better control and balance that you have looking on for, because its body has become designed exclusively for that. This roofing nailer will set any shingle accurately as a result of its adjustable shingle guide. Additionally, you’ll be able to improve between contact and sequential mode without difficulty because of a selectable trigger. Your shingles is not going to become damaged if you are using the DEWALT DWFP12658 as this machine has a special tool that stops this from happening.

Control and Safety
The DEWALT DWFP12658 also includes tool protection and safety because of its skid-resistant wear guards/pads. There is also an over-molded grip that will give you the control and luxury which you have been seeking. The DEWALT DWFP12658 can be viewed as as one of the top coil nailers available, and that´s no exaggeration at all. This tool carries a lightweight and engaging package you will adore straight away. Speed and safety were important objectives for the teams that built the DEWALT DWFP12658, and you’ll realize this fact immediately. Now you don’t have to book a gun, since the DEWALT DWFP12658 can be a cheap tool.

Pros
-The DEWALT DWFP12658 is extremely easy to adjust and load, so you will make well worth the cost if you buy this machine.-It’s got many safety measures that will assist you to avoid shooting yourself, so you’ll avoid many unexpected misfires.-It is a reliable roofing gun.-The device is well balance and nice.

Cons
-You’ll find out how the DEWALT DWFP12658 has some quirks. For instance, the DEWALT DWFP12658´s adjustable shingle guide will often move and wiggle loose.-You could have to regulate the equipment every so often.

We have discussed the DEWALT DWFP12658 and the magic this machine are able to do to suit your needs currently. The DEWALT DWFP12658 features a compact body design that gives you the control and balance that you’ve been looking for. Moreover, the DEWALT DWFP12658 is incredibly an easy task to adjust and contains a great deal of security features. Continue reading DEWALT DWFP12658

NYT TAG

tagtyperChoosing the correct replacement for an aged roof – or identifying the best choice for a new building – is no easy task. The perfect roofing solution for one building may be the worst option for another just down the street. That’s because no two buildings are precisely alike, even if they closely resemble each other.

So how do you choose a new roof, given all the choices in the marketplace? You can start by asking a series of questions, before you choose the roof, the roofing contractor or the manufacturer.

Need to know more, visit nyt tag

1. What is this building’s mission statement?

Before calls are made to roofing contractors or manufacturers, the first item to address is the company’s mission statement as it relates to the building.

Whether you are building new facilities or managing existing properties, you want to be confident that the roofing systems you select deliver the performance you expect. More often than not, the building itself dictates the appropriate roofing system specification.

You need to know as much about the building and its future as possible. Does the company plan to keep this building as part of its real estate assets for the next 10 to 20 years? Are there any plans to expand it in the near future, or to change its use? What are its current and future occupancy, insulation requirements, aesthetic priorities and even the maintenance schedules for rooftop equipment?

These and other mission statement issues will help shape answers to types of roofing to consider and how much of the capital budget is really needed for the job.

Start your questions with what is the building going to be used for. If it’s a spec building, maybe you only need a basic roof. But, if the facility has a special use, such as an airline reservation center with computers in it, then your considerations for roofing options are quite different.

For example, as more companies move toward operating 24 hours daily, seven days a week to satisfy global customers, the data center must never spring a rooftop leak. Water on computer systems generally spells disaster.

A special set of concerns arise for cooling-dominated climates. Does the roof contribute to air conditioning savings and address other key issues? Is it part of a total energy program? There is a growing concern about urban heat islands. Reflective, white roofs have become of interest in those areas for a few reasons. They keep the building cooler, reduce air conditioning costs and also minimize the heat-loading of the surrounding environment.

 

https://youtu.be/UiXcUT6NqUY

2. What physical and other elements influence the roofing system selection?

After identifying the goals and mission of a facility, it’s time to evaluate the building itself. You need to begin by looking at the building’s location and the attributes of its surrounding area. You need to examine building codes, weather trends, topography – even the direction the building faces.

The physical characteristics of the building are also crucial: size, shape, design, height and age.
You also need to look at the construction materials used to build the facility and the location of HVAC and fire protection equipment, particularly if either or both of these are partially or totally housed on the rooftop.

When it comes to roof replacement, you need to list the attributes of the roof area itself. It’s best to detail the roof’s size, shape, slope, deck construction, edge detailing, protrusions, rooftop access and existing roofing system. Along with this basic information, you need to find out why the original roof is no longer adequate.

3. What flexible-membrane roofing options are available?

SPRI, the association that represents sheet membrane and component suppliers to the commercial roofing industry, identifies three major categories of membranes: thermosets, thermoplastics and modified bitumens.

Thermoset membranes are made from rubber polymers. The most common is EPDM, often referred to as “rubber roofing.” These membranes are well suited to withstand the potentially damaging effects of sunlight and the common chemicals found on roofs. They are easily identified on the rooftop. Just look at the seams. Thermoset membranes require liquid or tape adhesives to form a watertight seal at the overlaps.
Thermoplastic membranes are based on plastic polymers. The most common is PVC, which is made flexible by adding plasticizers. Thermoplastic membranes have seams that are most commonly formed using heat welding. Most thermoplastic membranes are manufactured with a reinforcement layer, usually polyester or fiberglass to provide increased strength and dimensional stability.

Hypalon thermoplastic begins as a thermoplastic, but cures over time to become a thermoset. Like other thermoplastics, Hypalon materials are heat sealed at the seams.

Another thermoplastic hybrid is thermoplastic polyolefin (TPO), which combines the attributes of EPDM and PVC. TPO membranes do not cure after exposure to the elements and remain hot-air weldable throughout their service life. Most TPO membranes are reinforced with polyester, fiberglass or a combination of the two, but unreinforced TPO membranes are available.

Modified bitumen membranes incorporate the formulation and prefabrication advantages of flexible-membrane roofing with some of the traditional installation techniques used in built-up roofing. Modified bitumen sheets are factory-fabricated, composed of asphalt which is modified with a rubber or plastic polymer for increased flexibility, and combined with a reinforcement for added strength and stability.

4. Which type of membrane and attachment system are best for the building?

Many factors determine the best system for a particular building. For most buildings, there are a number of options and advantages that need to be weighed against the facility’s mission statement. The decision should not be made only on the basis of cost. Other important considerations for membranes are building height, wind exposure, anticipated roof traffic and aesthetics.

The attachment system also depends on the specific building’s characteristics. If the roof deck is able to withstand the weight, a ballasted roof may be the best option. But, if the slope of the roof is greater than 2 inches every foot, this system may not be appropriate. There are other limitations to ballasted systems, such as roof height, proximity to shorelines and other high wind zones, and the availability of ballast.
A steel or wood deck that easily accepts fasteners makes a good substrate for a mechanically fastened membrane. These systems can be designed to provide the necessary resistance to known wind forces and are not subject to slope limitations.

Another alternative is the fully adhered system, in which the membrane is attached to the prepared substrate using a specified adhesive. Depending on the membrane, the adhesive may be solvent- or water-based or asphalt. The finished surface of an adhered roof is smooth.

For those concerned with building aesthetics, colored membranes can make an attractive contribution to the building’s appearance.

5. Does all roofing material delivered to the job site bear the UL label?

If not, specify that it must. This is the only way you can guarantee that the roofing materials installed on your roof are the same materials tested by Underwriter’s Laboratories. Additionally, be sure that the roof assembly you buy or specify, which includes the insulation, is UL-classified and -labeled. Using an insulation other than what was tested with the roofing membrane may void the UL classification. If the UL Building Materials Directory does not list the roofing system you are sold, insist on verification of the classification in the form of a photocopy of the UL’s letter of approval. Continue reading NYT TAG